The Varlogic capacitor controller is used to measure reactive power and control capacitor banks to achieve the desired power factor. The device ranges include:

NR6 controls up to 6 steps.
NR12 controls up to 12 steps.
NRC12 controls up to 12 steps, with additional functions and optional Modbus RS485 communication port
Easy-to-read display parameters.
| Capacitor | ||||
| Description | Reference | |||
| EASYCAN 10 KVAR 440V | BLRC5100A120B44 | |||
| EASYCAN 15 KVAR 440V | BLRC5150A120B44 | |||
| EASYCAN 20 KVAR 440V | BLRC5200A120B44 | |||
| EASYCAN 25 KVAR 440V | BLRC5250A120B44 | |||
| EASYCAN 30.3 KVAR 440V | BLRC5303A120B44 | |||
| VARPLUS 40 KVAR 440V | BLRCH400A480B44 | |||
| VARPLUS 50 KVAR 440V | BLRCH500A400B44 | |||
| Capacitor for detune application | ||||
| VARPLUSCAN 33.9 KVAR 480V | BLRCH339A407B48 | |||
| Detune reactor | ||||
| Detune 5% 400V 50Hz 50kvar | LVR05500A40T | |||
| Detune 7% 400V 50Hz 50kvar | LVR07500A40T | |||
| Detune 14% 400V 50Hz 50kvar | LVR14500A40T | |||
| Capacitor Controller | ||||
| VARLOGIC RT6 | 51207 | |||
| VARLOGIC RT8 | 51209 | |||
| VARLOGIC RT12 | 51213 | |||
| VARLOGIC 6 steps, Modbus RS485, Measure real kvar, 2 cosphi setpoints | VPL06N | |||
| VARLOGIC 12 steps, Modbus RS485, Measure real kvar, 2 cosphi setpoints | VPL12N | |||
| Selection Table for Detune Reactor | ||||
| Network 400V, 50Hz Capacitor Voltage 480V 5.7%/7% Detuned Filer | ||||
| Effective Power (kvar) | QN at 480V | Capacitor Ref. | Switching: Contactor Ref | Protection: Easypact CVS(Icu=36kA) Ref. 2 |
| 25 | 33.9 | BLRCH339A407B48x1 | LC1D38x1 | LV5103341 |
| 50 | 67.9 | BLRCH339A407B48x2 | LC1D95x1 | LV5103371 |
| 100 | 136 | BLRCH339A407B48x4 | LC1F185x1 | LV5253321 |
| Network 400V, 50Hz Capacitor Voltage 525V 5.7%/7% Detuned Filter | ||||
| Effective Power (kvar) | QN at 480V | Capacitor Ref. | Switching: Contactor Ref | Protection: Easypact CVS(Icu=36kA) Ref. 2 |
| 40 | 80 | BLRCH400A480B52x2 | LC1D38x1 | LV5103341 |
| 50 | 100 | BLRCH400A480B52x2 | LC1D95x1 | LV5103371 |
| 100 | 160 | BLRCH400A480B52x4 | LC1F185x1 | LV5253321 |
| Capacitor | ||||
| Description | Reference | |||
| EASYCAN 10 KVAR 440V | BLRC5100A120B44 | |||
| EASYCAN 15 KVAR 440V | BLRC5150A120B44 | |||
| EASYCAN 20 KVAR 440V | BLRC5200A120B44 | |||
| EASYCAN 25 KVAR 440V | BLRC5250A120B44 | |||
| EASYCAN 30.3 KVAR 440V | BLRC5303A120B44 | |||
| VARPLUS 40 KVAR 440V | BLRCH400A480B44 | |||
| VARPLUS 50 KVAR 440V | BLRCH500A400B44 | |||
| Capacitor for detune application | ||||
| VARPLUSCAN 33.9 KVAR 480V | BLRCH339A407B48 | |||
| Detune reactor | ||||
| Detune 5% 400V 50Hz 50kvar | LVR05500A40T | |||
| Detune 7% 400V 50Hz 50kvar | LVR07500A40T | |||
| Detune 14% 400V 50Hz 50kvar | LVR14500A40T | |||
| Capacitor Controller | ||||
| VARLOGIC RT6 | 51207 | |||
| VARLOGIC RT8 | 51209 | |||
| VARLOGIC RT12 | 51213 | |||
| VARLOGIC 6 steps, Modbus RS485, Measure real kvar, 2 cosphi setpoints | VPL06N | |||
| VARLOGIC 12 steps, Modbus RS485, Measure real kvar, 2 cosphi setpoints | VPL12N | |||
| Selection Table for Detune Reactor | ||||
| Network 400V, 50Hz Capacitor Voltage 480V 5.7%/7% Detuned Filer | ||||
| Effective Power (kvar) | QN at 480V | Capacitor Ref. | Switching: Contactor Ref | Protection: Easypact CVS(Icu=36kA) Ref. 2 |
| 25 | 33.9 | BLRCH339A407B48x1 | LC1D38x1 | LV5103341 |
| 50 | 67.9 | BLRCH339A407B48x2 | LC1D95x1 | LV5103371 |
| 100 | 136 | BLRCH339A407B48x4 | LC1F185x1 | LV5253321 |
| Network 400V, 50Hz Capacitor Voltage 525V 5.7%/7% Detuned Filter | ||||
| Effective Power (kvar) | QN at 480V | Capacitor Ref. | Switching: Contactor Ref | Protection: Easypact CVS(Icu=36kA) Ref. 2 |
| 40 | 80 | BLRCH400A480B52x2 | LC1D38x1 | LV5103341 |
| 50 | 100 | BLRCH400A480B52x2 | LC1D95x1 | LV5103371 |
| 100 | 160 | BLRCH400A480B52x4 | LC1F185x1 | LV5253321 |